Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 465
Filter
1.
Chinese Journal of Ultrasonography ; (12): 600-607, 2023.
Article in Chinese | WPRIM | ID: wpr-992862

ABSTRACT

Objective:To explore the application value of two-dimensional speckle tracking echocardiography (2D-STE) in measuring the global longitudinal peak strain of the right atrium (PRAGLS) in normal fetuses and evaluating PRAGLS in assessing right atrial function in fetuses with moderate and severe tricuspid regurgitation (TR).Methods:A total of 25 fetuses diagnosed with moderate and severe TR, who underwent fetal echocardiography at Run Run Shaw Hospital, Zhejiang University College of Medicine between October 2020 and May 2022, were selected as the case group. Their gestational age ranged from 25.00(24.00, 30.00)weeks. Additionally, 100 normal singleton fetuses were chosen as the control group, with a gestational age of 25.83(23.00, 28.75)weeks. Standard basal or apical four-chamber clips were acquired and inputted into TOMTEC-ARENA offline cardiac analysis software for analysis. The fetal PRAGLS values of the two groups were obtained, as well as the routine obstetric ultrasound measurements and fetal echocardiographic parameters of both groups: fetal heart rate (FHR), biparietal diameter (BPD), femur length (FL), aortic annulus inner diameter (AO), pulmonary annulus inner diameter (PA), PA/AO ratio, right atrial end-systolic length (RAESL), right atrial end-systolic diameter (RAESD), right atrial end-systolic area (RAESA), right ventricular end-diastolic diameter (RVEDD), and tricuspid annular plane systolic excursion (TAPSE). The peak TR velocity and pressure gradient were simultaneously measured in the case group.The differences in fetal PRAGLS and other parameters between the two groups were compared and analyzed. The correlation between fetal PRAGLS and gestational age (GA) and routine measurements was assessed for both groups. Intra- and inter-observer repeatability tests were conducted using the intragroup correlation coefficient (ICC).Results:A significant difference in PRAGLS was observed between the two groups ( t=11.55, P<0.01). The TAPSE difference between the two groups was also statistically significant ( Z=3.45, P=0.01). Notable differences were found in AO, PA, PA/AO, RAESL, RAESD, and RAESA between the two groups (all P<0.05), but no significant differences were identified in age, GA, FHR, BPD, FL, and RVEDD between the two groups (all P>0.05). PRAGLS in the control group exhibited a moderate negative correlation with GA ( r=-0.47, P<0.01) and were correlated with BPD, FL, AO, PA, RAESL, RAESD, RAESA, and RVEDD ( r=-0.50, -0.46, -0.39, -0.43, -0.45, -0.36, -0.43, -0.32, all P<0.05). No significant correlation was observed with maternal age, FHR, PA/AO, and TAPSE (all P>0.05). No significant correlation between PRAGLS and GA or other conventional parameters was found in the case group (all P>0.05). The inter-measurer and intra-measurer ICC of PRAGLS in the control group were 0.87 and 0.79, respectively, while the inter-measurer and intra-measurer ICC of PRAGLS in the case group were 0.94 and 0.97, respectively, demonstrating good consistency. Conclusions:2D-STE exhibits strong feasibility and reproducibility in assessing fetal atrial function.Fetuses with moderate and severe TR display decreased PRAGLS, suggesting impaired right atrial reservoir function. Right atrial strain introduces a novel method for evaluating fetal cardiac function.

2.
Chinese Journal of Ultrasonography ; (12): 590-599, 2023.
Article in Chinese | WPRIM | ID: wpr-992861

ABSTRACT

Objective:To investigate the effect of instantaneous flow rate on the consistency of diagnostic accuracy of severe degenerative mitral regurgitation (DMR) using proximal isovelocity surface area (PISA).Methods:From June 2019 to June 2021, 75 patients with DMR who underwent echocardiography in Department of Echocardiography of Zhongshan Hospital, Fudan University were prospectively enrolled. The instantaneous flow rate of DMR during the systolic phase was calculated using M-mode PISA(PISA M-mode), and a time-integrated curve was plotted. Regurgitant volume (RVol) and effective regurgitant orifice area (EROA) were calculated by traditional PISA (PISA max), pair PISA (PISA pair), and PISA M-mode, respectively. RVol acquired from cardiac magnetic resonance (CMR) volumetric method in 22 patients of the enrolled patients. The correlation and consistency of RVol acquired between the three PISA methods and CMR were compared. Agreement of diagnostic accuracy of severe mitral regurgitation (sMR) acquired between the three PISA methods and multi-parameter algorithm by American Society of Echocardiography (ASE) was analyzed using Cohen′s Kappa analysis. Results:The curve of instantaneous flow rate of DMR showed unimodal pattern with the peak at mid-late systolic phase. The correlation of RVol acquired between PISA methods and CMR was moderate for PISA max and PISA pair ( r=0.77, 0.80, both P<0.001), whereas PISA M-mode presented strong correlation with CMR ( r=0.87, P<0.001). RVol acquired from PISA max was larger than that of CMR[(69.1±37.1) ml vs (49.0±29.0)ml, P=0.002]. Both PISA max and PISA pair were shown moderate agreement of diagnostic accuracy of sMR with ASE multi-parameters algorithm (RVol: κ=0.496, 0.525, both P<0.001; EROA: κ=0.570, 0.578, both P<0.001), while PISA M-mode presented strong agreement (RVol: κ=0.867 and EROA: κ=0.802, both P<0.001). Conclusions:Based on the unimodal pattern of instantaneous flow rate in patients with DMR, PISA max may significantly overestimate RVol, exposing a significant proportion of patients with DMR to unnecessary MR surgery. PISA M-mode presents better correlation and consistency with CMR on the quantification of RVol compared with PISA max and PISA pair, and may improve the diagnostic accuracy of quantification of sMR using PISA.

3.
Chinese Journal of Ultrasonography ; (12): 303-310, 2023.
Article in Chinese | WPRIM | ID: wpr-992835

ABSTRACT

Objective:To investigate the correlations between serum E selectin, intercellular adhesion molecule 1 (ICAM-1), vascular cell adhesion molecule 1 (VCAM-1) and left ventricular geometry and function in patients with obstructive sleep apnea syndrome (OSAS) combined with prehypertension (pre-HT).Methods:A total of 462 patients with pre-HT and OSAS diagnosed by polysomnography (PSG) in the sleep monitoring unit of the Department of Respiratory and Critical Care Medicine at the First Hospital of Shanxi Medical University from July 2019 to July 2022 were restrospectively analysed, and 52 patients with pure pre-HT (pre-HT group) and 73 patients with pure OSAS (OSAS group) in the same period were selected as the control group. OSAS and pre-HT patients were divided into four groups according to left ventricular geometry: normal geometry (NG) group, concentric remodeling (CR) group, eccentric hypertrophy (EH) group and concentric hypertrophy (CH) group. The general clinical data, PSG parameters, blood biochemical parameters and left ventricular structure and function parameters were compared among the six groups. Pearson correlation and multivariate Logistic regression were used to analyze the correlation between E-selection, ICAM-1, VCAM-1, general clinical data, PSG parameters, blood biochemical parameters with left ventricular geometry and function.Results:①Serum E selectin, ICAM-1, and VCAM-1 concentrations increased sequentially from the NG, CR, and EH to CH groups, with the most significant increase in CH group (all P<0.05). In addition, there were statistically significant differences in age, body mass index (BMI), OSAS severity, neck circumference, waist circumference, systolic blood pressure (SBP), diastolic blood pressure (DBP), Glu, lowest oxygen saturation (Lowest-SaO 2), mean oxygen saturation (Mean-SaO 2), percentage of time with oxygen saturation below 90% of total sleep time (T90), left ventricular end-diastolic diameter (LVEDd), interventricular septal thickness (IVST), left ventricular posterior wall thickness (LVPWT), left ventricular mass index (LVMI), relative ventricular wall thickness (RWT), left ventricular ejection fraction (LVEF), peak mitral early diastolic flow velocity/peak mitral late diastolic flow velocity (E/A), E wave deceleration time (DT), A wave duration (AD), and isovolumic relaxation time (IVRT), and overall long-axis longitudinal strain (GLS) and so on(all P<0.05). ②Pearson correlation analysis showed that E selectin was negatively correlated with LVEF, E/A, e′, E/e′, IVRT, and GLS ( r=-0.236, -0.131, -0.224, -0.215, -0.285, -0.336; all P<0.05). ICAM-1 was negatively correlated with LVEF, E, E/A, e′, IVRT, and GLS( r=-0.130, -0.129, -0.104, -0.351, -0.252, -0.259; all P<0.05). VCAM-1 was negatively correlated with E, e′, and IVRT ( r=-0.132, -0.312, -0.387; all P<0.001). ③Multifactorial logistic regression analysis showed that E selectin and VCAM-1 were independently correlated with EH (β=1.139, OR=3.124, P=0.030; β=1.288, OR=3.626, P<0.001) and with CH (β=1.178, OR=3.248, P=0.013; β=1.108, OR=3.028, P<0.001). Conclusions:E selection and VCAM-1 were independently correlated with hypertrophic left ventricular geometry, suggesting that E selectin and VCAM-1 may be involved in the process of abnormal left ventricular structure and function in patients with OSAS combined with pre-HT.

4.
Chinese Journal of Ultrasonography ; (12): 189-197, 2023.
Article in Chinese | WPRIM | ID: wpr-992822

ABSTRACT

Objective:To evaluate the fetal heart shape and function in tetralogy of Fallot (TOF) by fetal heart quantitative analysis (fetal HQ).Methods:A total of 52 fetuses with TOF diagnosed by fetal echocardiography and 200 normal fetuses matched with their gestational weeks from March 2020 to March 2022 at Sir Run Run Shaw Hospital, Zhejiang University were retrospectively evaluated. The basic parameters of fetal cardiac blood vessels in the two groups were measured by fetal HQ technology and conventional M-mode ultrasound technology: aortic valve diameter(AV), pulmonary artery valve diameter(PV), main pulmonary artery diameter (MPA) and Z-score. The overall morphometric measurements including end-diastolic length diameter, transverse diameter, area, and global spherical index (GSI) of the fetal heart in the 4-chamber view(4CV), area and length of the right and left ventricles and their ratios. Measurements of left and right ventricular function included ejection fraction (EF), fraction area change rate (FAC), tricuspid annular plane systolic excursion (TAPSE), left and right ventricular global longitudinal strain (GLS), and left and right ventricular end-diastolic diameter (ED), spherical index (SI), and fractional shortening rate (FS) of 24-segments. The differences of above parameters between TOF group and control group were compared. In addition, the relationships between the absolute value of left and right ventricular GLS of TOF fetus and PV/AV, PV Z-score and MPA Z-score were analyzed. The optimal critical values of GSI, left ventricular EF and left ventricular FAC of TOF fetus were determined by ROC curve, and their corresponding sensitivity and specificity were obtained.Results:Compared with control group, there were significant differences in 4CV end-diastolic length, area, GSI, left ventricular area, left ventricular length, left ventricular EF, left ventricular FAC and left ventricular GLS in TOF group (all P<0.05). There were significant differences in ED between left ventricular 15-24 segments and right ventricular 1-21 segments (all P<0.05). There were significant differences in SI between left ventricular 1-16 segments, 21-24 segments and all segments of right ventricle (all P<0.05). The differences in FS were statistically significant (all P<0.05) when comparing all segments of the left ventricle and 1-2 segments of the right ventricular, and the remaining parameters were not statistically significant (all P>0.05). The left ventricular GLS absolute value of TOF fetuses was positively correlated with PV/AV, PV Z-score and MPA Z-score( rs=0.338, 0.441 and 0.458, all P<0.05), the right ventricular GLS absolute value of TOF fetuses was positively correlated with PV AV, PV Z-score and MPA Z-score( rs=0.418, 0.368 and 0.338, all P<0.05). The optimal critical values of GSI, left ventricular EF, and left ventricular FAC in the diagnosis of fetal TOF were 1.19, 59.05%, and 44.4%, respectively. At this time, the sensitivities of diagnosis of TOF were 0.78, 0.75, and 0.80, respectively. The specificities were 0.88, 0.88 and 0.83, respectively. The areas under ROC curve were 0.89, 0.88 and 0.89, respectively. Conclusions:Fetal HQ technology can provide a simple and reliable quantitative evaluation of fetal heart shape and function, and provide certain theoretical parameters for the study of fetal heart shape and function.

5.
Acta Pharmaceutica Sinica ; (12): 1128-1137, 2023.
Article in Chinese | WPRIM | ID: wpr-978692

ABSTRACT

As a treasure resource of novel drug lead compounds, how to rapidly and high-efficiently screen and isolate active components from natural products is critical. Thanks to its high resolution, high automation and flexible integration, online two-dimensional liquid chromatography has great potential for screening active ingredients from complex matrices by integrating a highly specific bio-recognition process into a two-dimensional liquid chromatography system before, on or after the column separation. This review comprehensively summarized recent developments, applications and shortcomings of online two-dimensional liquid chromatography for natural product screening from different integration modes, including pre-column, on-column and post-column screening methods.

6.
Acta Pharmaceutica Sinica B ; (6): 1303-1317, 2023.
Article in English | WPRIM | ID: wpr-971759

ABSTRACT

In situ and real-time monitoring of responsive drug release is critical for the assessment of pharmacodynamics in chemotherapy. In this study, a novel pH-responsive nanosystem is proposed for real-time monitoring of drug release and chemo-phototherapy by surface-enhanced Raman spectroscopy (SERS). The Fe3O4@Au@Ag nanoparticles (NPs) deposited graphene oxide (GO) nanocomposites with a high SERS activity and stability are synthesized and labeled with a Raman reporter 4-mercaptophenylboronic acid (4-MPBA) to form SERS probes (GO-Fe3O4@Au@Ag-MPBA). Furthermore, doxorubicin (DOX) is attached to SERS probes through a pH-responsive linker boronic ester (GO-Fe3O4@Au@Ag-MPBA-DOX), accompanying the 4-MPBA signal change in SERS. After the entry into tumor, the breakage of boronic ester in the acidic environment gives rise to the release of DOX and the recovery of 4-MPBA SERS signal. Thus, the DOX dynamic release can be monitored by the real-time changes of 4-MPBA SERS spectra. Additionally, the strong T2 magnetic resonance (MR) signal and NIR photothermal transduction efficiency of the nanocomposites make it available for MR imaging and photothermal therapy (PTT). Altogether, this GO-Fe3O4@Au@Ag-MPBA-DOX can simultaneously fulfill the synergistic combination of cancer cell targeting, pH-sensitive drug release, SERS-traceable detection and MR imaging, endowing it great potential for SERS/MR imaging-guided efficient chemo-phototherapy on cancer treatment.

7.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 523-528, 2023.
Article in Chinese | WPRIM | ID: wpr-986062

ABSTRACT

Objective: To evaluate the right ventricular function using two-dimensional speckle tracking echocardiography (2-D STE) and analyze the associated risk factors of right ventricular dysfunction in patients with silicosis. Methods: All 104 patients with silicosis treated in the Department of Occupational Medicine and Toxicology in Beijing Chao-Yang Hospital, Capital Medical University from May 2021 to September 2022 were enrolled in this study in October 2022. The clinical information of patients such as general data, arterial blood gas analysis and pulmonary function test were collected. The right ventricular function of patients was evaluated by 2-D STE-derived right ventricular free wall longitudinal strain (RVFWLS) and conventional echocardiographic-derived parameters, including right ventricular fractional area change (RVFAC), tricuspid annular plane systolic excursion (TAPSE) and doppler tissue imaging-derived tricuspid lateral annular systolic velocity (S'), respectively. Based on their RVFWLS, the patients were divided into right ventricular dysfunction group and normal right ventricular function group. Risk factors for right ventricular dysfunction in patients with silicosis were analyzed using binary logistic regression analysis. Results: A total of 104 silicosis patients were enrolled, with aneverage age (65.52±11.18) years old, among whom including 57 cases diagnosed with stage Ⅰ/Ⅱ silicosis and 47 cases diagnosed with stage Ⅲ silicosis. 26 (25.00%) patients concurrent right ventricular dysfunction. The abnormal rates of RVFAC, TAPSE and S' in patients were 16.35% (17 cases), 21.15% (22 cases) and 6.73% (7 cases), respectively. The RVFAC and TAPSE in right ventricular dysfunction group were lower than those in normal right ventricular function group, and the incidence of pulmonary arterial systolic pressure ≥36 mmHg was higher than that in normal right ventricular function group (P<0.05). Logistic regression analysis showed that arterial partial pressure of oxygen (OR=0.932, 95%CI: 0.885-0.981, P=0.007) was the protective factor, and the forced expiratory volume in 1 second (FEV(1)) /forced vital capacity (FVC) ratio<70% (OR=5.484, 95%CI: 1.049-28.662, P=0.044) and stage Ⅲ silicosis (OR=6.343, 95%CI: 1.698-23.697, P=0.007) were the risk factors for silicosis patients concurrent right ventricular dysfunction. Conclusion: The incidence of right ventricular dysfunction is higher in patients with stage Ⅲ silicosis than that in patients with stage Ⅰ/Ⅱ silicosis. Using 2-D STE can help the early detection of silicosis with right ventricular dysfunction. Hypoxemia, airflow limitation and the stage Ⅲ silicosis are the risk factors for silicosis patients concurrent right ventricular dysfunction.


Subject(s)
Humans , Middle Aged , Aged , Ventricular Dysfunction, Right/etiology , Ventricular Function, Right , Echocardiography , Risk Factors , Silicosis/diagnostic imaging
8.
Journal of Biomedical Engineering ; (6): 499-507, 2023.
Article in Chinese | WPRIM | ID: wpr-981568

ABSTRACT

The increasing prevalence of the aging population, and inadequate and uneven distribution of medical resources, have led to a growing demand for telemedicine services. Gait disturbance is a primary symptom of neurological disorders such as Parkinson's disease (PD). This study proposed a novel approach for the quantitative assessment and analysis of gait disturbance from two-dimensional (2D) videos captured using smartphones. The approach used a convolutional pose machine to extract human body joints and a gait phase segmentation algorithm based on node motion characteristics to identify the gait phase. Moreover, it extracted features of the upper and lower limbs. A height ratio-based spatial feature extraction method was proposed that effectively captures spatial information. The proposed method underwent validation via error analysis, correction compensation, and accuracy verification using the motion capture system. Specifically, the proposed method achieved an extracted step length error of less than 3 cm. The proposed method underwent clinical validation, recruiting 64 patients with Parkinson's disease and 46 healthy controls of the same age group. Various gait indicators were statistically analyzed using three classic classification methods, with the random forest method achieving a classification accuracy of 91%. This method provides an objective, convenient, and intelligent solution for telemedicine focused on movement disorders in neurological diseases.


Subject(s)
Humans , Aged , Parkinson Disease/diagnosis , Aging , Algorithms , Gait , Lower Extremity
9.
Acta Academiae Medicinae Sinicae ; (6): 361-365, 2023.
Article in Chinese | WPRIM | ID: wpr-981279

ABSTRACT

Objective To evaluate extrathyroidal extension (ETE) in papillary thyroid microcarcinoma (PTMC) with three-dimensional tomographic ultrasound imaging (3D-TUI). Methods A total of 97 thyroid nodules of 79 patients with PTMC treated in PUMC Hospital from February 2016 to January 2018 were included in this study.Two ultrasound experts performed independent blinded assessment of the relationship between thyroid nodules and thyroid capsule by two-dimensional ultrasound (2D-US) and 3D-TUI.The results of 2D-US and 3D-TUI in evaluating ETE were compared with intraoperative findings and postoperative histological and pathological results. Results Among the 97 nodules,54 (55.7%) nodules had ETE.The diagnostic sensitivity (68.5% vs.37.0%;χ2=10.737,P=0.002),accuracy (74.5% vs.56.7%;χ2=6.686,P=0.015),and area under the receiver operating characteristic curve[0.761 (95%CI=0.677-0.845) vs.0.592 (95%CI=0.504-0.680);Z=3.500,P<0.001] of 3D-TUI were higher than those of 2D-US.However,3D-TUI and 2D-US showed no significant difference in the specificity (84.1% vs.81.4%;χ2=0.081,P=0.776),negative predictive value (67.9% vs.50.7%;χ2=3.645,P=0.066),or positive predictive value (84.1% vs.71.4%;χ2=1.663,P=0.240). Conclusion Compared with 2D-US,3D-TUI demonstrates increased diagnostic efficiency for ETE of PTMC.


Subject(s)
Humans , Thyroid Nodule , Thyroid Neoplasms/diagnosis , Carcinoma, Papillary/pathology , Ultrasonography/methods , Retrospective Studies
10.
Journal de la Faculté de Médecine d'Oran ; 6(2): 819-824, 2023. figures
Article in French | AIM | ID: biblio-1415186

ABSTRACT

La double discordance est une cardiopathie congénitale complexe extrêmement rare, elle se caractérise par une discordance auriculo-ventriculaire suivie d'une autre discordance ventriculo-artérielle. Son diagnostic est posé généralement à l'âge adulte par des examens d'imagerie. Son pronostic dépend essentiellement des autres malformations congénitales cardiaques associées, des arythmies et des troubles de la conduction, ainsi que de la fonction systolique du ventricule droit en position systémique. Nous rapportons le cas d'un patient âgé de 23 ans, porteur d'une cardiopathie congénitale complexe cyanogène. Il s'agit d'une double discordance associée à une large communication interventriculaire sous aortique avec un shunt inversé et une hypoplasie de l'artère pulmonaire. Ce diagnostic a été confirmé par l'imagerie multimodale. Non opéré, le patient a vu son stade fonctionnel s'aggraver rapidement avec une dyspnée qui est passée d'un stade I à un stade III-IV de la New York Heart Association (NYHA), et apparition de signes hypoxiques et congestifs. A travers cette observation, nous avons précisé les caractéristiques anatomocliniques de cette cardiopathie congénitale complexe cyanogène, son exploration, ses options thérapeutiques, ainsi que le rôle péjoratif de son association avec d'autres malformations congénitales.


Double discordance is an extremely rare complex congenital heart disease; It is characterized by atrioventricular discordance followed by another ventriculo-arterial discordance. Its diagnosis is usually made in adulthood by imaging examinations. Its prognosis depends mainly on other associated congenital heart defects, arrhythmias and disorders of the conduction, as well as systolic function of the right ventricle in the systemic position. We report the case of a 23-year-old patient with a complex cyanogen heart disease.It is a double discordance associated to an interventricular communication with reverse shunt and an hypoplasia of the pulmonary artery.This Diagnosis was confirmed in multimodal imaging. Non-operated, the patient saw his functional status worsen rapidly with dyspnea which went from stage I to stage III-IV of the New York Heart Association (NYHA), and appearance of hypoxic and congestive signs. Through this observation, we have clarified the anatomoclinical characteristics of this complex congenital cyanogens heart disease, the necessary explorations and the different therapeutic options, as well as the pejorative role of its association with other congenital malformations.


Subject(s)
Humans , Female , Pulmonary Artery , Therapeutics , Transposition of Great Vessels , Heart Defects, Congenital , Arrhythmias, Cardiac , Congenital Abnormalities
11.
Rev. cuba. angiol. cir. vasc ; 23(3): e354, sept.-dic. 2022. graf
Article in Spanish | LILACS, CUMED | ID: biblio-1408204

ABSTRACT

La enfermedad arterial periférica se considera la mayor causa de hospitalización, con riesgo de amputación de la extremidad afectada y muerte debido a la enfermedad per se o sus complicaciones. Se reporta la experiencia del tratamiento a un paciente con macroangiopatía diabética, estenosis del 64 por ciento de la arteria ilíaca izquierda y afectación de los segmentos fémoro-poplíteos bilaterales, al cual, a través de un acceso percutáneo vía arteria braquial izquierda, se le realizó revascularización mediante la implantación de stent de cromo-cobalto liberado por balón catéter. El objetivo de este estudio fue describir la utilidad del 2D-ASD y su valor como herramienta para determinar el transproceder y la repercusión en el flujo sanguíneo de la revascularización realizada, y establecer un pronóstico funcional para el paciente. Se utilizó la angiografía por perfusión bidimensional como herramienta para evaluar el éxito técnico del proceder y la repercusión inmediata en la perfusión distal de la extremidad afecta, y describir la utilidad de la escala paramétrica de colores y las curvas de densidad en función del tiempo obtenidos en el estudio(AU)


Peripheral artery disease is considered the leading cause of hospitalization, with risk of amputation of the affected limb and death due to the disease per se or its complications. It is reported the experience of treatment in a patient with diabetic macroangiopathy, stenosis of 64 precent of the left iliac artery and involvement of the bilateral femoro-popliteal segments, to which, through a percutaneous access via the left brachial artery, revascularization was performed through the implantation of cobalt-chromium stent released by balloon catheter. The objective of this study was to describe the usefulness of 2D-ASD and its value as a tool to determine the trans-procedure and the impact on blood flow of the revascularization performed, and to establish a functional prognosis for the patient. Two-dimensional perfusion angiography was used as a tool to evaluate the technical success of the procedure and the immediate impact on distal perfusion of the affected limb, and to describe the usefulness of the parametric color scale and density curves as a function of the time obtained in the study(AU)


Subject(s)
Angiography/adverse effects , Peripheral Arterial Disease/complications , Amputation, Surgical/methods , Hospitalization
12.
Rev. cuba. angiol. cir. vasc ; 23(3)sept.-dic. 2022.
Article in Spanish | LILACS, CUMED | ID: biblio-1441488

ABSTRACT

La enfermedad arterial periférica se considera la mayor causa de hospitalización, con riesgo de amputación de la extremidad afectada y muerte debido a la enfermedad per se o sus complicaciones. Se reporta la experiencia del tratamiento a un paciente con macroangiopatía diabética, estenosis del 64 por ciento de la arteria ilíaca izquierda y afectación de los segmentos fémoro-poplíteos bilaterales, al cual, a través de un acceso percutáneo vía arteria braquial izquierda, se le realizó revascularización mediante la implantación de stent de cromo-cobalto liberado por balón catéter. El objetivo de este estudio fue describir la utilidad del 2D-ASD y su valor como herramienta para determinar el transproceder y la repercusión en el flujo sanguíneo de la revascularización realizada, y establecer un pronóstico funcional para el paciente. Se utilizó la angiografía por perfusión bidimensional como herramienta para evaluar el éxito técnico del proceder y la repercusión inmediata en la perfusión distal de la extremidad afecta, y describir la utilidad de la escala paramétrica de colores y las curvas de densidad en función del tiempo obtenidos en el estudio(AU)


Peripheral artery disease is considered the leading cause of hospitalization, with risk of amputation of the affected limb and death due to the disease per se or its complications. It is reported the experience of treatment in a patient with diabetic macroangiopathy, stenosis of 64 percent of the left iliac artery and involvement of the bilateral femoro-popliteal segments, to which, through a percutaneous access via the left brachial artery, revascularization was performed through the implantation of cobalt-chromium stent released by balloon catheter. The objective of this study was to describe the usefulness of 2D-ASD and its value as a tool to determine the trans-procedure and the impact on blood flow of the revascularization performed, and to establish a functional prognosis for the patient. Two-dimensional perfusion angiography was used as a tool to evaluate the technical success of the procedure and the immediate impact on distal perfusion of the affected limb, and to describe the usefulness of the parametric color scale and density curves as a function of the time obtained in the study(AU)


Subject(s)
Humans , Male , Middle Aged , Peripheral Arterial Disease
13.
Article | IMSEAR | ID: sea-220271

ABSTRACT

Background: Atrial septal defects lead to left to right shunt, the volume of the shunt is determined by RV/LV compliance, defect size, and LA/RA pressure. RV volume overload and pulmonary over circulation are caused by a simple ASD because the RV is more compliant than the LV. The aim of our study was to assess changes in RV systolic function before and after ASD closure either by surgery or transcatheter closure. Methods: This study was conducted on 70 patients diagnosed with ASD Secundum and had subdivided into two groups A (surgical closure) group, and B (percutaneous device closure) group. All patients had been assessed by transthoracic Echocardiography examination for RV systolic Function 24 h before ASD closure, and 6 months after closure. Results: There was a significant decrease in the right ventricle systolic function indices (TAPSE, FAC, Tissue Doppler S wave velocity, and global longitudinal free wall strain) after ASD closure either by surgery or by transcatheter device closure Conclusions: The right ventricle's size and function are affected by a large shunt caused by an ASD secudium. ASD and its consequent volume overload resulted in higher RV myocardial contraction, leading to an increase in strain values and RV systolic function indices, which were reduced and returned to normal values when the left-to-right shunt was eliminated, and the defect was closed.

14.
Chinese Journal of Ultrasonography ; (12): 1053-1058, 2022.
Article in Chinese | WPRIM | ID: wpr-992794

ABSTRACT

Objective:To explore the value of liver stiffness and spleen stiffness measured by two-dimensional shear wave elastography (2D-SWE) in predicting high-risk varices (HRV) with compensated cirrhosis patients.Methods:Seventy patients with compensated cirrhosis who attended the First Hospital of Lanzhou University from November 2019 to April 2022 were recruited. All patients underwent examinations of liver stiffness measurement (LSM) and spleen stiffness measurement (SSM) by 2D-SWE. Binary logistic regression was used to analyze the risk factors affecting the occurrence of HRV. The diagnostic performances of LSM, liver stiffness (by 2D-SWE)-spleen length-to-platelet (LSPS) score, and SSM in predicting HRV were compared.Results:SSM was not technically feasible in 6/70 (8.6%) patients due to small volume of spleen.Among 64 patients with compensated cirrhosis, 30/64 (46.9%) were HRV. Binary multivariate Logistic regression analysis showed that SSM and platelet counts were independent influencing factors for predicting HRV, with OR values of 1.126 ( P=0.006) and 0.971 ( P=0.039), respectively. The area under the receiver operating characteristic curve (AUC) of LSM, LSPS score, and SSM were 0.660, 0.828 and 0.858, respectively. The AUCs of SSM and LSPS score were significantly higher than that of LSM ( P<0.05), but there was no statistical difference between SSM and LSPS score ( P=0.608). Conclusions:LSM and SSM measured by 2D-SWE have high success rate. SSM and LSPS score have high value in predicting HRV in patients with compensated cirrhosis, and the diagnostic performances of the above two methods are significantly higher than that of LSM.

15.
Chinese Journal of Ultrasonography ; (12): 1046-1052, 2022.
Article in Chinese | WPRIM | ID: wpr-992793

ABSTRACT

Objective:To explore the application value of two-dimensional speckle tracking imaging (2D-STI) in evaluating diaphragm function, and to compare the ability of 2D-STI and conventional diaphragm ultrasonography in diagnosing diaphragmatic dysfunction and evaluating disease severity in patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD).Methods:A total of 58 AECOPD patients admitted to the First Affiliated Hospital of Xi′an Jiaotong University from January to October 2021 were retrospectively enrolled as AECOPD group, and 34 healthy subjects were recruited as control group during the same period. Repeatability test of diaphragmatic 2D-STI was performed. According to modified Medical Research Council (mMRC) dyspnea scores system and COPD Assessment Test (CAT), mMRC 0-1 and CAT<10 was classified as group A, mMRC≥2 and CAT≥10 was classified as group B. The baseline characteristics, conventional diaphragm ultrasonography parameters(thickening fraction and excursion) and 2D-STI parameters (longitudinal and radial strains) were compared between the AECOPD group and the control group, and the Spearman correlation between parameters of AECOPD group and forced expiratory volume in one second (FEV1) was analyzed. The differences of these parameters between group A and B were also compared. The ROC curve of conventional diaphragm ultrasonography parameters and 2D-STI parameters was plotted to differentiate group A from group B, and the diagnostic efficacy was evaluated.Results:Great intra- and inter-observer reproducibility was found for all diaphragmatic 2D-STI parameters, with ICCs above 0.80 for all measurements. The control group and the AECOPD group did not differ in age, sex and body mass index( P>0.05), whereas there were significant differences in smoking history, lung function, bilateral thickening fraction, excursion, longitudinal and radial strains( P<0.05). Compared with control group, patients in group A had a significant increase in diaphragm thickness ( P<0.05), while there was no significant difference in that between group B and control group ( P>0.05). The bilateral longitudinal strains, radial strains and thickening fraction of diaphragm were linearly correlated with FEV1 (right side rs=0.828, 0.794, 0.843, respectively; all P<0.001; left side rs=0.757, 0.704, 0.752, respectively; all P<0.001 ), while the correlation between excursion and FEV1 was not significant(right side rs=0.247, left side rs=0.253; all P>0.05). There were significant differences in bilateral longitudinal strains, radial strains and thickening fraction between group A and group B(all P<0.05), whereas there was no significant difference in excursion between the two groups ( P>0.05). ROC analysis showed bilateral longitudinal and radial strains had higher accuracy in distinguishing group A from group B than thickening fraction and excursion(right side AUCs 0.90, 0.84, 0.78 and 0.62, respectively; left side AUCs 0.85, 0.83, 0.77 and 0.62, respectively). Conclusions:2D-STI is a real-time noninvasive technique for diaphragm function assessment, which has high clinical value. Compared with conventional ultrasonography, 2D-STI shows more accuracy and effectiveness in diagnosing diaphragmatic dysfunction and evaluating disease severity of patients with AECOPD.

16.
Chinese Journal of Medical Education Research ; (12): 1509-1513, 2022.
Article in Chinese | WPRIM | ID: wpr-955701

ABSTRACT

Objective:To compare the application effects of high-definition two-dimensional (HD-2D) and glasses-free three-dimensional (GF-3D) display systems in thoracoscopy teaching.Methods:A total of 40 clinical medicine interns with no surgical experience from The First Affiliated Hospital of Guangzhou Medical University were recruited and were required to participate in a 1-week training course of endoscopy. They were then randomly allocated to the HD-2D group and GF-3D group and asked to perform three tasks: peg transfer, circular cutting, and suture knotting. Their performance was measured with a system that scored speed and precision. SPSS 25.0 was used to conduct t-test, Pearson Chi-square test and Fisher exact test for the comparison. Results:The mean time for the peg transfer test in GF-3D group was shorter than that in HD-2D group, without statistically significant difference [(63.20±21.11) s vs. (71.15± 17.26) s, P = 0.212]. The mean time for the circular cutting test in GF-3D group was shorter than that in HD-2D group, without statistically significant difference [(112.50±16.67) s vs. (118.15±24.43) s, P=0.410]. The mean time for the suture knotting test in GF-3D group was shorter than that in HD-2D group, with statistically significant difference [(301.50±32.77) s vs. (341.75±57.23) s, P=0.019]. The total score in GF-3D group was higher than that in HD-2D group, with statistically significant difference [(78.33±5.88) points vs. (72.08±6.83) points, P=0.005]. Conclusion:The GF-3D display system is clearly superior to the HD-2D system because it reduces the surgical learning curve, and is therefore suitable for basic teaching and skills training.

17.
Chinese Journal of Medical Education Research ; (12): 826-829, 2022.
Article in Chinese | WPRIM | ID: wpr-955542

ABSTRACT

The gross specimens and tissue slices used for traditional experimental pathology curriculum are fragile, and some specimens or slices are difficult to be supplemented. Besides, the classroom and schedule for experimental pathology teaching are inflexible. Therefore, the teaching effects for experimental pathology course are limited. The development of digital technology has promoted the teaching reform of medical experimental curriculum. We have digitalized the gross specimens and tissue slices to preserve and expand the samples, and constructed pathological sample repository containing both physical samples and digital samples. Furthermore, we have established a platform for remote access, and thus improved the flexibility and autonomy of study for experimental pathology curriculum. Additionally, we have integrated clinical information of the teaching samples, and interpreted the specimens with the assistance of two-dimensional code technology and voice broadcast technology, to realize human-computer interactive learning. The questionnaire shows that the application of pathological sample repository in experimental teaching has improved student learning effect and recognition.

18.
Chinese Journal of Ultrasonography ; (12): 312-317, 2022.
Article in Chinese | WPRIM | ID: wpr-932405

ABSTRACT

Objective:To detect the changes of liver stiffness before and after chemotherapy in postoperative breast cancer patients using the two-dimensional shear wave elastography (2D-SWE) technique, and analyze its correlation with liver serum indexs, then discuss the application value of 2D-SWE technique in the quantitative diagnosis for chemotherapeutic liver injury.Methods:Sixty breast cancer patients underwent postoperative chemotherapy in Qilu Hospital of Shandong University from January 2021 to November 2021 were included. Conventional two-dimensional ultrasound, 2D-SWE and the serum tests including alanine aminotransferase(ALT), aspartate aminotransferase(AST), γ-glutamyltransferase(γ-GT), alkaline phosphatase(AKP) were performed before and after chemotherapy, respectively. The medians of ElastQ Imaging stiffness (EQI meds) of the whole liver and different liver segments (S4, S5/S6, S7/S8) before and after chemotherapy were measured and compared. The EQI meds of different liver segments (S4, S5/S6, S7/S8) after chemotherapy were compared. The correlation between EQI med of the whole liver and serum indexes after chemotherapy was analyzed. Results:①Compared with before chemotherapy, the EQI meds of the whole liver and different liver segments after chemotherapy were significantly decreased ( P<0.001, respectively). ②The EQI meds among different liver segments were different after chemotherapy ( F=7.489, P=0.001). Moreover, the EQI meds of S5/S6 and S7/S8 were significantly lower than those of S4 after chemotherapy ( P=0.002, 0.001). ③The EQI med of the whole liver was negatively correlated with ALT, AST, and γ-GT ( r=-0.776, P<0.001; r=-0.656, P<0.001; r=-0.428, P=0.010), while there was no correlation between the EQI med of the whole liver and AKP ( r=-0.146, P=0.267). Conclusions:2D-SWE is expected to be a new, real-time, noninvasive and quantitative method to evaluate the changes of liver stiffness before and after chemotherapy in postoperative patients, thus provides a promising method for the early clinical diagnosis of chemotherapy-induced liver injury in breast cancer patients.

19.
Chinese Journal of Ultrasonography ; (12): 289-294, 2022.
Article in Chinese | WPRIM | ID: wpr-932402

ABSTRACT

Objective:To evaluate the cardiac function and systolic dyssynchrony of fetuses exposed to maternal autoimmune antibodies (anti-SSA/Ro60, anti-SSA/Ro52 and anti-SSB/La) by using two-dimensional speckle tracking imaging (2D-STI).Methods:A total of 52 pregnant women with singleton pregnancy in the Affiliated Hospital of Inner Mongolia Medical University from July 2018 to November 2020 were selected. Eighteen fetuses of mothers with autoimmune antibodies were enrolled as autoimmune disease (AD) group and 34 fetuses of healthy mothers without antibodies were included as control group. Maternal baseline characteristics, fetoplacental Doppler parameters, and conventional echocardiographic data of two groups were prospectively collected. The systolic global and regional longitudinal strain of left and right ventricles (LV and RV) and the time to peak strain of regional myocardium were measured using 2D-STI. The differences in time to peak strain between the LV free wall and RV free wall (two-chamber dyssynchrony, 2C-DYS) and between the septum and LV free wall (one-chamber dyssynchrony, 1C-DYS) were also calculated.Results:There were no significant differences between the two groups in conventional systolic and diastolic functional parameters for the LV and RV(all P>0.05). The myocardial deformation parameters and 2C-DYS obtained by 2D-STI showed no statistical differences between two groups(all P>0.05). However, 1C-DYS was significantly more prolonged in the AD group than control group[28.50(13.50, 39.25)ms vs 19.50(8.00, 29.25)ms, P=0.042]. Conclusions:LV systolic mechanical dyssynchrony in fetuses of mothers with autoimmune antibodies suggests in-utero subclinical damage of the cardiac conduction system.

20.
Chinese Journal of Ultrasonography ; (12): 283-288, 2022.
Article in Chinese | WPRIM | ID: wpr-932401

ABSTRACT

Objective:To investigate the value of routine echocardiography and two-dimensional speckle tracking echocardiography in evaluating the left ventricular function of patients with gestational diabetes mellitus (GDM) prenatal and postpartum.Methods:Twenty-two patients with clinically confirmed GDM in Xiamen Zhongshan Hospital from October 2019 to December 2020 were chosed as the case group, and 22 healthy pregnant women were chosed as the control group. Routine echocardiography and two-dimensional speckle tracking echocardiography were performed in the third trimester and about 3 months postpartum. Routine echocardiographic parameters and longitudinal strain (LS), circumfirential strain (CS) were obtained. The correlation between global longitudinal strain(GLS) and other cardiac function parameters was analyzed. The relationship between clinical parameters of pregnant women and GLS was analyzed by multiple linear regression.Results:In comparison with the control group, the interventricular septal diameter at disatole, left ventricular posterior wall diameter at diastole, Tei index were increased, e′ was decreased in GDM group(all P<0.05); the GLS, each layer LS of GDM group were lower than the control group(all P<0.05), the GLS, each layer LS and torsion parameters were improved at 3 months postpartum(all P<0.05). There was a negative correlation between GLS and Tei( r=-0.224, P=0.036). GLS and HbA 1c was linearly correlated with the regression equation: GLS=-27.458+ 1.534×HbA 1c( R2=0.115). Conclusions:The left heart function of pregnant women with GDM in the third trimester are significantly impaired, but the cardiac function recovers to a certain extent about 3 months after delivery. Two-dimentional speckle-tracking echocardiography is a more accurate and sensitive technique to evaluate the early damage of cardiac function in pregnant women with GDM.

SELECTION OF CITATIONS
SEARCH DETAIL